Product

navigate_next

Terrestrial Navigation System

navigate_next

DAR-6200T


DAR-6200T

MF R-Mode Exciter

The MF R-Mode Exciter is a device that receives a reference timing data from a reference timing generator, generates an MF R-Mode signal that combines an MSK signal and two CW signals, measures the quality of the output signal, and controls the generated CW signal to be synchronized to the reference time through TOT control.


Function

Signal generating

  • Generating two independent CW signals with frequency setting, phase and output level control
  • Generating MSK signal and two CW signals synchronized to externally provided UTC timing

Signal Measurement

  • Quality Measurement Based on SAE9990 Specification
  • First Pulse and 8 Pulse Quality Measurement in Group A/B
  • Measuring Transmission Signal Quality(Spectrum, MSK MER, CW C/N, CW vs 1PPS)

RTCM

  • Standard RTCM message transmission
  • RTCM transmission rate control
  • Decoding and Encoding of Received RTCM Messages
  • Standard MSK demodulation function for decoding RTCM message

TOT Control

  • Automatic TOT control

Specs

Performance
MSK Signal Frequency control283.5kHz ~325kHz @1Hz Step
RTCM Bit Rate setting50/100/200bps
MSK Signal Timing control1ns Step based on MSK phase 
CW1/2 Signal Frequency control283.25kHz ~325.25kHz @1Hz Step
CW1/2 Signal Timing control1ns Step based on CW phase
Amplitude Control0~100%, 1% Step
MSK Bit timing uncertainty<1ns @ MSK Phase vs. 1PPS
CW1/2 Signal timing uncertainty<1ns @CW Phase vs. 1PPS
Phase estimator uncertainty<1ns @CW Phase vs. 1PPS(when CNR>45)
Manual mode2ns Step(uncertainty <1ns) 
Auto mode lock range2ns ~20ns
Input Signal1PPS, 10MHz, MF R-Mode Feedback signal
Output SignalMF R-Mode signal